Venturi / Orificemeter Tube Apparatus (Model : TATSM-VENTURI-ORIFICE)

Venturi / Orificemeter Tube Apparatus (Model : TATSM-VENTURI-ORIFICE)

175,000.00 70,000.00

Key Features

 

•  Includes Venturi meter

 

•  Works with Tatsam’s Digital Hydraulic Bench (H1F2)* for easy installation

 

•  Direct measurement of head loss

 

•  Multi-tube manometer shows pressure at various points

Key Specifications

 

•  Venturi meter, orifice plate and rotameter

 

•  Sudden enlargement and 90° elbow

 

•  Eleven manometer tubes

 

•  Downstream flow control valve

 

 

Description

DESCRIPTION

 

The product has a horizontal pipe that includes a Venturi meter, orifice plate and pressure tappings. An elbow connects the pipe to a rotameter (gap-type flow meter) with further pressure tappings. The pressure tappings are connected to manometers held on a vertical panel behind the pipe work. The manometers measure and show pressure distribution against a calibrated scale. To perform experiments, students connect the product to the hydraulic bench supply, and set it to a low, steady flow through the apparatus.

 

Water from the bench then flows through the Venturi meter, through a sudden enlargement, a settling length and the orifice plate. It then flows around the elbow, through the rotameter, then a flow control valve, finally returning to the hydraulic bench. The control valve is downstream, so it does not cause any upstream turbulence.

 

To adjust the water level in the manometer tubes, students connect a hand-pump (included) to the valve above the manometer tubes.

 

Detailed Specifications

 

The apparatus consists of :

 

  • A Centrifugal pump of 25mm x 25mm with 1/2 HP Motor (ISI – Kirloskar Make)

 

  • S. Sump Tank 80 Ltr. to collect the water.

 

  • S. Measuring Tank 30Ltr fitted with piezometer tube to measure the discharge. Damper is used to collect the water in M.S. MEASURING TANK for certain time.

 

  • I. pipe of internal dia 25mm and Gunmetal ISI mark Control Valve and regulating valves are used to circulate water.

 

  • Bye-pass line is also used to regulate the discharge. This apparatus consists of metallic/venturimeter. The openings from inlet and throat are connected to U tube mercury manometer to measure the head difference. The tanks are well FRC fiber coated insided to prevent rust hence increase the life of tank.

Reviews

There are no reviews yet.

Be the first to review “Venturi / Orificemeter Tube Apparatus (Model : TATSM-VENTURI-ORIFICE)”

Your email address will not be published. Required fields are marked *